Categories: HagerMCB

3250612235568 – EW006_E

EW006_E - Minicontactor 9A-AC3 / 24V DC

Order code: 3250612235568
Full Product Code: 3250612235568
Downloads
Buy

Specifications

General Information
Type of pole: 3 P
Compatible with DIN rail mounting: yes
Type of supply voltage: DC
Rated operational voltage Ue: 690 V
Rated insulation voltage: 690 V
DC control voltage: 24 V
Acceptable current rating with AC1: 20 A
Rated operational current in AC3: 9 A
Thermal rated current outside of housings: 20 A
Contact rating with 400 V in AC3: 4 kW
Electric endurance in number of cycles: 500000
Number of mechanical operations: 10000000
Relative humidity (without condensation): 45 … 85 %
Depth of installed product: 58 mm
Height of installed product: 54 mm
Width of installed product: 45 mm
Type of connection: with screw
Connection cross section of access and exit with screws, for flexible conductor: 2/5,5 mm²
Connection cross-section of input and output with screws, for massive conductors: 2/5,5 mm²
Number of auxiliary contacts as normally open contact: 1
Quantity of NO contacts: 3
Category of use: AC3
Standard text: IEC 60 947-4-1
Altitude: 2000 m
Storage temperature: -40 to 80 °C
Device family: EW
admin

Recent Posts

Kesalahan Spesifikasi Kabel dalam Proyek Industri dan Dampaknya terhadap Umur Instalasi

Kesalahan spesifikasi kabel proyek industri dapat menyebabkan overheating, penurunan performa sistem, hingga memperpendek umur instalasi…

4 weeks ago

Mengapa Sistem Proteksi Listrik Industri Harus Dirancang Berlapis? Peran MCB dan MCB Domae dalam Mencegah Kerugian Produksi

Sistem proteksi listrik industri harus dirancang berlapis karena mampu membatasi dampak gangguan hanya pada area…

1 month ago

Perencanaan Sistem Kelistrikan Modular untuk Pabrik yang Sering Ekspansi

Sistem kelistrikan modular untuk pabrik adalah pendekatan desain instalasi listrik yang memungkinkan penambahan mesin, lini…

1 month ago

Kenapa Biaya Lampu Proyek Sering Membengkak di Tengah Jalan? Ini Titik Masalahnya

Biaya lampu proyek membengkak biasanya bukan hanya karena harga unit lampu mahal, tetapi karena kesalahan…

2 months ago

Salah Pilih Kabel Listrik? Dampaknya Bisa Jadi Masalah Besar di Kemudian Hari

Salah pilih kabel listrik dapat menyebabkan panas berlebih, korsleting, gangguan sistem, hingga kerusakan instalasi jangka…

2 months ago

Jangan Anggap Sepele: Alasan Produk Kelistrikan Bersertifikasi Wajib Digunakan

Produk kelistrikan bersertifikasi wajib digunakan karena telah lulus standar keamanan resmi, memiliki spesifikasi yang konsisten,…

2 months ago

This website uses cookies.