LV432876 – Circuit breaker Compact NSX630F – Micrologic 2.3 – 630 A – 3 poles 3d

Circuit breaker Compact NSX630F - Micrologic 2.3 - 630 A - 3 poles 3d

Order code: LV432876
Full Product Code: LV432876

Downloads
Buy

Specifications

General Information
range
Compact
product name
Compact NSX
product or component type
Circuit breaker
device short name
Compact NSX630F
device application
Distribution
poles description
3P
protected poles description
3t
network type
AC
network frequency
50/60 Hz
[In] rated current
630 A at 40 °C
[Ui] rated insulation voltage
800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ue] rated operational voltage
690 V AC 50/60 Hz
Breaking capacity code
F 36 kA 415 V AC
breaking capacity
40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 240 V AC 50/60 Hz conforming to UL 508
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 480 V AC 50/60 Hz conforming to UL 508
20 kA at 600 V AC 50/60 Hz conforming to UL 508
20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
utilisation category
Category A
trip unit name
Micrologic 2.3
trip unit technology
Electronic
trip unit protection functions
LSoI
pollution degree
3 conforming to IEC 60664-1

 

admin

Recent Posts

Produk di Rak Toko Terlihat Kusam? Atur Ulang Pencahayaan Display agar Barang Lebih Menarik Perhatian

Cara paling efektif mengoptimalkan pencahayaan rak display minimarket dan retail dengan lampu led dan smart…

3 weeks ago

Tagihan Listrik Naik tapi Koridor Gedung Sering Gelap? Solusi Hemat Listrik Tanpa Mematikan Lampu Keamanan

Cara paling efektif untuk hemat listrik koridor dan tangga darurat gedung dengan lampu led dan…

1 month ago

Kabel dan Stop Kontak Berserakan di Ruang Kerja? Begini Cara Bikin Layout Listrik Kantor Lebih Rapi dan Aman

Cara terbaik membuat layout instalasi listrik kantor rapi dengan stop kontak lantai dan pipa conduit…

1 month ago

Area Loading Dock Gudang Terlalu Gelap? Atasi dengan Pengaturan Lampu Flood LED yang Tepat

Pengaturan solusi pencahayaan loading dock gudang dengan lampu flood led tahan cuaca yang paling efektif…

1 month ago

Panduan Memilih Pipa Conduit, Cable Glands, dan Kabel untuk Lingkungan Industri Ekstrem

Lingkungan industri dengan suhu tinggi, getaran kuat, hingga paparan bahan kimia menuntut instalasi listrik yang…

2 months ago

Cara Merancang Panel Listrik Gedung yang Efisien dan Sesuai Aturan PUIL

Mengelola infrastruktur listrik gedung, terutama yang berskala komersial, bukan sekadar soal memasang panel dan menyusun…

2 months ago

This website uses cookies.