LV431830 – Circuit breaker Compact NSX250N – TMD – 250 A – 3 poles 3d

Circuit breaker Compact NSX250N - TMD - 250 A - 3 poles 3d

Order code: LV431830
Full Product Code: LV431830

Downloads
Buy

Specifications

General Information
range
Compact
product name
Compact NSX
product or component type
Circuit breaker
device short name
Compact NSX250N
device application
Distribution
poles description
3P
protected poles description
3t
network type
AC
network frequency
50/60 Hz
[In] rated current
250 A at 40 °C
[Ui] rated insulation voltage
800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ue] rated operational voltage
690 V AC 50/60 Hz
Breaking capacity code
N 50 kA 415 V AC
breaking capacity
85 kA at 240 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 480 V AC 50/60 Hz conforming to UL 508
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 600 V AC 50/60 Hz conforming to UL 508
[Ics] rated service breaking capacity
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
utilisation category
Category A
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit protection functions
LI
pollution degree
3 conforming to IEC 60664-1

 

admin

Recent Posts

Desain Pencahayaan Modern untuk Area Resepsionis Kantor: Gunakan Downlight LED yang Tepat

Menciptakan ruang resepsionis yang menarik tidak hanya bergantung pada desain interior, tetapi juga pada bagaimana…

4 days ago

Cara Memasang MCB yang Tepat agar Lebih Hemat Listrik

Mengetahui cara memasang MCB dengan benar sangat penting untuk memastikan keamanan instalasi listrik di rumah,…

1 week ago

Meningkatkan Efisiensi Energi di Hotel Bisnis dengan Time Switch dan Motion Sensor

Di tengah meningkatnya kesadaran akan pentingnya efisiensi energi dan keberlanjutan, hotel bisnis dituntut untuk mengelola…

2 weeks ago

Lampu Anti Ledakan untuk Gudang Bahan Kimia: Panduan Khusus Instalasi Aman

Gudang bahan kimia adalah salah satu area kerja yang paling rawan risiko kebakaran dan ledakan…

3 weeks ago

Tips Menentukan Pencahayaan yang Tepat untuk Area Tambang Bawah Tanah

Pencahayaan yang tepat di tambang bawah tanah bukan sekadar soal visibilitas, melainkan menyangkut langsung keselamatan…

4 weeks ago

Peran Lampu Sorot Tahan Ledakan di Area Industri Berisiko Tinggi

Dalam dunia industri, keamanan adalah prioritas utama, terutama di area yang berisiko tinggi seperti tambang…

2 months ago

This website uses cookies.